ct(0.1) prints, but ct(0.01) does not print with eh3check.on at ID11
Not urgent (this is @wright). @papillon It looks like a threading glitch or some printing to console is not serialised? You should see "(abort with Ctrl-c) [elapsed time 0.0 s] Checking Undulator positions ..." in the output below, but the browser does not render it, so I guess there are invisible characters or "\r" issues?
NSCOPE [1945]: ct(.01)
0%| (abort with Ctrl-c) [elapsed time 0.0 s] Checking Undulator positions ...
48%|██████████████████████████████████████████████████████████████████████▊ (abort with Ctrl-c) [elapsed time 0.2 s] Checking OH1 valves ...
Out [1945]: Scan(name=ct, path='not saved')
NSCOPE [1946]: ct(.1)
0%| (abort with Ctrl-c) [elapsed time 0.0 s] Checking Undulator positions ...
4%|██████▎ (abort with Ctrl-c) [elapsed time 0.2 s] Checking OH1 valves ...
pico6 = 9114.69 ( 91146.9 /s) keithley
current = 67.6300 mA ( 676.300 mA/s) machinfo
sbcurr = 4.63000 mA ( 46.3000 mA/s) machinfo
refill = 1581.00 sec ( 15810.0 sec/s) machinfo
roi1_avg = 12.9414 ( 129.414 /s) basler_eh32
roi1_max = 1954.00 ( 19540.0 /s) basler_eh32
roi1_min = 0.00000 ( 0.00000 /s) basler_eh32
roi1_std = 36.2080 ( 362.080 /s) basler_eh32
roi1_sum = 1.01577e+06 ( 1.01577e+07 /s) basler_eh32
fpico6 = 917885. ( 9.17885e+06 /s) p201_21
sec = 0.100000 s ( 1.00000 s/s) p201_21
Au_det0 = 0 ( 0.00000 /s) mca
Ce_det0 = 0 ( 0.00000 /s) mca
W_det0 = 0 ( 0.00000 /s) mca
Zr_det0 = 0 ( 0.00000 /s) mca
all_det0 = 3 ( 30.0000 /s) mca
deadtime_det0 = 0.413822 ( 4.13822 /s) mca
energy_livetime_det0 = 0.0586176 ( 0.586176 /s) mca
events_det0 = 10 ( 100.000 /s) mca
icr_det0 = 170.597 ( 1705.97 /s) mca
ocr_det0 = 100.000 ( 1000.00 /s) mca
realtime_det0 = 0.0999997 ( 0.999997 /s) mca
trigger_livetime_det0 = 0.0996499 ( 0.996499 /s) mca
triggers_det0 = 17 ( 170.000 /s) mca
Out [1946]: Scan(name=ct, path='not saved')
Edited by Pierre-Olivier Autran