magnet knobs
PR says:
independent knobs for skew, quad, … such that a set of magnets is set above the existing values, like for resonance strengths on top of correction strenghts. concept of correction levels? correction = sum of levels. today levels are design, correction, resonance.
FOR PS Test lifetime with SF2A off and then with SF2A and SF2E off. Same for SD1A SD1E, SD1B/D groups. This would allow to stop one rack element and replace it manually.
Knobs for optimisation (over 4 cells, then recursive):
SF2A + delta SF2E - delta SF2A + delta SF2E - delta SF2A - delta SF2E + delta SF2A - delta SF2E + delta
Same for oct
Or
SF2A + 2delta SF2E + delta SF2A - delta SF2E - 2 delta SF2A - 2 delta SF2E - delta SF2A + delta SF2E + 2 delta
Same for oct
Edited by Simone Liuzzo