Closed
Milestone
Oct 23, 2018–Nov 6, 2018
MDT 06 November 8.00-14.00
commissioining simulation.
INTERVENTION on booster crate in the early morning 8.00 (ACU intervention on diagnostics crate). This should have no impact with us. in that time, we switch BPMs in TbT.
MDT preliminary Plan:
- CV correction test
- inject beam off energy 1ms (high neutron dose) from booster N.C. (check triggering)
- injection with wrong RF frequency (500Hz).
- correct with BestCor option
- Nasty Steerer procedure
- tune from first turns (tunes for operation lattice and theory lattice, correction based on this values?)
- minimize correctors with absolute COD correction (test OrbitCorrection)
- K3/K4, bump amplitude, setting with InjBumpClosure
- first turn with aperture limitations
- tune scan after beam accumulation
- RM after beam accumulation
from first turns continue correction: orbit correction, tune correction, optimal tune WP search, qem/sempanel, chromaticity correction, ...
take many screenshots.
FUTURE MDT's of if there is time.
- bad initial condition (few BPMs see signal) (large radiation)
- re-test on SY